Large Lamp Modules with 4 pole change over relay
Cells 6 8 10
Case C C C
Module S563 S583 S573
Lamp Watts

Figures quoted are Ballast Lumen Factors, %

T8 30/36 18 23 27
58 12* 17 20
70   13* 14*
T12 40 15 19 22
65 11 14 16
85 10* 14*
DEL 26 30
TEL 32 26
TC-L 18
24 23
34 23
36 19 25
40 24* 25
55 16* 22
80 14*
2D 28 24 30 33
38 19 21 24
F 36 19 22 27
CC CC CC
CC = Modules with cold cathodes
This module / lamp is not suitable for remote mounting above 0.5 m
Figures quoted are ballast lumen factors, %
Where BLFs are entered in red or marked * - remove link or open switch

Page Ref: WP0054 Issue 00 August 08

2 & 3 Cell Data